Quality supervision of the Nord-Lock solution on a Siemens 501F in Puebla

In February 2024 we supervised the quality of the Nord-Lock solution with mechanical tensioners installed on the casing of a Siemens 501F gas turbine at San Lorenzo Potencia, in Puebla. Our job was to make sure the joint was assembled and loaded as designed, so it would hold under operating conditions.

Superbolt mechanical tensioners on a 501F casing
Superbolt mechanical tensioners on a 501F casing

Why the 501F casing needs it

On the 501F the horizontal and vertical joints between cylinders meet at the 4-way joint. Thermal cycling distorts the cylinders, the faces lose contact and combustion air escapes. Welded leak boxes only contain the leak; the mechanical solution closes the joint.

What a quality supervision checks

  • Hardware against the kit list and the drawings.
  • Cleaning of holes and faces before assembly.
  • Torque sequence of every jackbolt and its record.
  • Final gap readings and photo report for the outage file.

From one unit in Puebla to the North American fleet

That experience became field execution: from April 2025 to June 2026 our crews completed 35 installations and re-installations of the 4-way joint solution on W501F units in Texas, Arizona, Oregon, California, Alabama and Ontario. How the 4-way joint is installed